Charging voltage
- Old Sb-Sb:
- max 14,5V (2,42 V per cell)
- float 13,2V (2,2Vpc)
- Ca-Ca (most batteries up to 110Ah):
- 16,25V (2,71 Vpc)
- float 13.1V (2.18Vpc)
- Gel (old):
- 14,1V (2,35 Vpc)
- float 13,2V (2,2 Vpc)
- AGM:
- 14,9 V (2,48Vpc)
- limit/hold: 15,6 (2,6 Vpc)
- float: 13,6V (2,27 Vpc)
- Sb-Ca (deep discharge / special / over 110Ah):
- 14.55V (2,43Vpc)
- absorption: 16,45 (2,73 Vpc)
- float: 13,1V (2,18 Vpc)