meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

vm:proxmox:kvm:windows:migrate_from_vb [2020/10/06 08:07]
niziak created
vm:proxmox:kvm:windows:migrate_from_vb [2020/10/06 10:12] (current)
niziak
Line 20: Line 20:
     * Remove created Hard Disc (scsi0)     * Remove created Hard Disc (scsi0)
   * Import disc images (repeat for all VDI discs)   * Import disc images (repeat for all VDI discs)
-    * As RAW images with all benefits (compression,​ thin provisioning,​ snapshots) ​of ''​local-zfs''​ storage: <code bash>qm importdisk 701 WIN7_C.vdi local-zfs</​code>​+    * As RAW images with all benefits (compression,​ thin provisioning,​ snapshots) ​or ''​rbd''​ or ''​local-zfs''​ storage: <code bash>qm importdisk 701 WIN7_C.vdi local-zfs</​code>​
       * 21743 MB VDI compacted file occupied 15,2G on ZFS with compression ratio 1.24x       * 21743 MB VDI compacted file occupied 15,2G on ZFS with compression ratio 1.24x
     * As QCOW2 files on every file storage: <code bash>qm importdisk 701 WIN7_C.vdi local -format qcow2</​code>​     * As QCOW2 files on every file storage: <code bash>qm importdisk 701 WIN7_C.vdi local -format qcow2</​code>​
Line 26: Line 26:
     * <code bash>qm set 701 --scsi<​N>​ local-zfs:​vm-701-disk-<​N>,​discard=on,​size=64G</​code>​     * <code bash>qm set 701 --scsi<​N>​ local-zfs:​vm-701-disk-<​N>,​discard=on,​size=64G</​code>​
     * NOTE: ''​discard=on''​ should be enabled for thin provisioned storage to reclaim unused space     * NOTE: ''​discard=on''​ should be enabled for thin provisioned storage to reclaim unused space
-  * Switch SCSI to IDE: <code bash>sed -i '​s/​scsi/​ide/​g'​ /​etc/​pve/​qemu-server/​701.conf</​code>​ +  * Change SCSI to IDE/SATA: 
-    * Manually correct numbering conflict with CD-ROM ​ide drive +    * For i440FX machine: ​Switch SCSI to IDE: <code bash>sed -i '​s/​scsi/​ide/​g'​ /​etc/​pve/​qemu-server/​701.conf</​code>​ 
-    * Setup correct boot order+      * Manually correct numbering conflict with IDE CD-ROM drive  ​* ​ 
 +    ​* For Q35 machine: Switch SCSI to SATA: <code bash>sed -i '​s/​scsi/​sata/​g'​ /​etc/​pve/​qemu-server/​701.conf</​code>​ 
 +  ​* Setup correct boot order
   * Add one dummy (small size) hard disc to SCSI controller   * Add one dummy (small size) hard disc to SCSI controller
   * Enable QEMU Guest Agent   * Enable QEMU Guest Agent
Line 41: Line 43:
     * Setup correct boot order     * Setup correct boot order
  
-sed -i 's/​ide/​scsi/​g' ​/​etc/​pve/​qemu-server/​701.conf+=== Issues === 
 + 
 +''​Can't create IDE unit 1, bus supports only 1 units''​ 
 +Q35 machine has only master IDEs. Use ''​sata0'',​ ''​sata1''​ and so on. 
 + 
  
 ==== NOT WORKING: Importing OVA file ==== ==== NOT WORKING: Importing OVA file ====