meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
hw:server:raid [2021/04/08 19:38] niziakhw:server:raid [2023/02/05 20:21] niziak
Line 1: Line 1:
 +====== RAID ======
 +  * RAID0 - striping
 +  * RAID1 - mirror
 +  * RAID5
 +    * do not use
 +    * very slow write
 +    * rebuild takes days, and during rebuild another disk may fail = fatal
 +  * RAID6 - striping with double parity (5+2, 13+2).
 +    * minimum 4 disks
 +    * allow 2 disk failure
 +    * slower write than RAID5 (requires udpate parity on 2 disks)
 +
 +Recommended levels for safety: 
 +  * RAID10 = RAID 1 + 0 = i.e two mirrors (RAID1) stripped as RAID0
 +  * RAID6
 +  * RAID60 = RAID 6 + 0 - two RAID6 sets stripped as RAID0
 +
 ====== Raid controllers ====== ====== Raid controllers ======
   * controllers where RAID can be disabled, and all disks are exposed to host are called: ''HBA'', ''JBOD'', ''IT-MODE''   * controllers where RAID can be disabled, and all disks are exposed to host are called: ''HBA'', ''JBOD'', ''IT-MODE''
Line 33: Line 50:
       * no possibility to expose disks directly to host (trick is to create one RAID0 per disk)       * no possibility to expose disks directly to host (trick is to create one RAID0 per disk)
     * **H200**     * **H200**
-      * plain HBA+      * **plain HBA**
       * no raid       * no raid
       * JBOD - all disks exposed to host (so called IT-mode)       * JBOD - all disks exposed to host (so called IT-mode)
     * H310     * H310
-      * plain HBA+      * **plain HBA** 
 +    * H330 
 +      * 8 internal ports 
 +      * can be flashed into HBA [[https://forums.servethehome.com/index.php?threads/flash-crossflash-dell-h330-raid-card-to-hba330-12gbps-hba-it-firmware.25498/|Flash/Crossflash DELL H330 RAID Card to HBA330/12Gbps HBA IT Firmware]]