meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
hw:server:proliant380eg8:ssacli [2021/09/16 10:03]
niziak
hw:server:proliant380eg8:ssacli [2021/10/10 20:46] (current)
niziak
Line 1: Line 1:
 ====== ssacli ====== ====== ssacli ======
 +
 +Source: [[https://​be-virtual.net/​hpe-storage-controller-management-ssacli/​|HPE Storage Controller Management (ssacli) ]]
  
 <code bash> <code bash>
Line 17: Line 19:
 ssacli ctrl slot=2 array all show detail ssacli ctrl slot=2 array all show detail
 </​code>​ </​code>​
 +
 +====== rescan for new drives ======
 +
 +''​ssacli rescan''​
  
 ====== cache ratio ====== ====== cache ratio ======
Line 33: Line 39:
 Show rebuild priority: Show rebuild priority:
 ''​ssacli ctrl slot=2 modify rp=?''​ ''​ssacli ctrl slot=2 modify rp=?''​
 +
 +====== switch to HBA mode ======
 +<code bash>
 +ssacli ctrl slot=2 ld all delete
 +ssacli controller slot=2 modify hbamode=on
 +</​code>​
 +
 +
  
 ===== RAID5 ===== ===== RAID5 =====
Line 51: Line 65:
 ssacli ctrl slot=2 array B show detail ssacli ctrl slot=2 array B show detail
  
 +# Force Linux to detect size change:
 +echo 1 > /​sys/​class/​scsi_disk/​0\:​1\:​0\:​1/​device/​rescan
 +
 +# echo 1 > /​sys/​block/​sdb/​device/​rescan
 +# partprobe /dev/sdb
  
 </​code>​ </​code>​