meta data for this page
Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
hw:server:proliant380eg8:ssacli [2021/09/16 10:03] niziak |
hw:server:proliant380eg8:ssacli [2021/10/10 20:46] (current) niziak |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== ssacli ====== | ====== ssacli ====== | ||
+ | |||
+ | Source: [[https://be-virtual.net/hpe-storage-controller-management-ssacli/|HPE Storage Controller Management (ssacli) ]] | ||
<code bash> | <code bash> | ||
Line 17: | Line 19: | ||
ssacli ctrl slot=2 array all show detail | ssacli ctrl slot=2 array all show detail | ||
</code> | </code> | ||
+ | |||
+ | ====== rescan for new drives ====== | ||
+ | |||
+ | ''ssacli rescan'' | ||
====== cache ratio ====== | ====== cache ratio ====== | ||
Line 33: | Line 39: | ||
Show rebuild priority: | Show rebuild priority: | ||
''ssacli ctrl slot=2 modify rp=?'' | ''ssacli ctrl slot=2 modify rp=?'' | ||
+ | |||
+ | ====== switch to HBA mode ====== | ||
+ | <code bash> | ||
+ | ssacli ctrl slot=2 ld all delete | ||
+ | ssacli controller slot=2 modify hbamode=on | ||
+ | </code> | ||
+ | |||
+ | |||
===== RAID5 ===== | ===== RAID5 ===== | ||
Line 51: | Line 65: | ||
ssacli ctrl slot=2 array B show detail | ssacli ctrl slot=2 array B show detail | ||
+ | # Force Linux to detect size change: | ||
+ | echo 1 > /sys/class/scsi_disk/0\:1\:0\:1/device/rescan | ||
+ | |||
+ | # echo 1 > /sys/block/sdb/device/rescan | ||
+ | # partprobe /dev/sdb | ||
</code> | </code> |